3 Mart 2015 Salı

none of the requested files were backed up(2)

none of the requested files were backed up(2)

"NT AUTHORITY\SYSTEM" is not able to access the database "DB NAme" under the current security context


http://www.symantec.com/docs/HOWTO85432

For SQL Server 2008 and earlier, the sysadmin role is automatically applied to the NT AUTHORITY\SYSTEM and BUILTIN\Administrators groups.

You can use Local System for the logon accounts for the NetBackup services.

For SQL Server 2012, you must first apply the sysadmin role manually to the NT AUTHORITY\SYSTEM or the BUILTIN\Administrators group.

Then you can use Local System for the logon accounts for the NetBackup services.

29 Ocak 2015 Perşembe

NetBackup_7.5_CLIENTS_tar-gz - Dosyalarını birleştirmek

https://fileconnect.symantec.com adresinden indirilen dosyları birleştirmek.

NetBackup_7.5_CLIENTS_tar-gz.1of3
NetBackup_7.5_CLIENTS_tar-gz.2of3
NetBackup_7.5_CLIENTS_tar-gz.2of3


Linux/UNIX systems:
cat "NetBackup_7.5_CLIENTS_tar-gz.1of3" "NetBackup_7.5_CLIENTS_tar-gz.2of3" "NetBackup_7.5_CLIENTS_tar-gz.3of3" > "NetBackup_7.5_CLIENTS.tar.gz"

extract 
tar xzf NetBackup_7.5_CLIENTS.tar.gz


Windows systems:
copy /b "NetBackup_7.5_CLIENTS_tar-gz.1of3"+"NetBackup_7.5_CLIENTS_tar-gz.2of3"+"NetBackup_7.5_CLIENTS_tar-gz.3of3" "NetBackup_7.5_CLIENTS.tar.gz"

User Account Control (UAC) is enabled on this host. - Windows Server 2012

Windows Server 2012 sunucu üzerinde UAC özelliğini kapatmak için registry içerisinde aşağıdaki değişikliği yapmak gerekiyor.


HKEY_LOCAL_MACHINE

SOFTWARE Microsoft > Windows > CurrentVersion > Policies > system içerisindeki

EnableLUA değerini 0 yapmak gerekiyor.

21 Ocak 2015 Çarşamba

Invalid Virtual Machines in VMware

ESX sunucu üzerinde aşağıdaki komut çalıştırılarak VM ID bulunur.

vim-cmd vmsvc/reload (VM ID numarası) komutu ile de online hale getirilir.


vim-cmd vmsvc/getallvms | grep invalid

~ # vim-cmd vmsvc/getallvms | grep invalid

Skipping invalid VM '1'

~ # vim-cmd vmsvc/reload 1

27 Ağustos 2014 Çarşamba

How to apply esxi 5.5 update 1 with esxcli (update-from-esxi5.5-5.5_update01.zip)

How to apply esxi 5.5 update 1 with esxcli [update-from-esxi5.5-5.5_update01.zip]

Update için gerekli olan dosyayı vmware sitesinden indirip sunucunun local diskine kopyalıyoruz.
Sunucya ssh ile bağlanarak aşağıdaki komutu çalıştıroyoruz
~ # esxcli software vib install -d /vmfs/volumes/taltesx1/update-from-esxi5.5-5.5_update01.zip
Installation Result
 Message: The update completed successfully, but the system needs to be rebooted for the changes to be effective.
 Reboot Required: true

Restart sonrası vmware -vl   komutu ile versiyonumuzu görebiliyoruz.

~ # vmware -vl
VMware ESXi 5.5.0 build-1623387

VMware ESXi 5.5.0 Update 1

VIBs Installed: VMware_bootbank_elxnet_10.0.100.0v-1vmw.550.0.0.1331820,
VMware_bootbank_esx-base_5.5.0-1.15.1623387,
VMware_bootbank_ima-qla4xxx_2.01.31-1vm w.550.0.0.1331820,
VMware_bootbank_lpfc_10.0.100.1-1vmw.550.0.0.1331820, VMware_bootbank_lsimsgpt3_00.255.03.03-1vmw.550.1.15.1623387,
VMware_bootbank_misc-cni c-register_1.72.1.v50.1i-1vmw.550.0.0.1331820,
VMware_bootbank_misc-drivers_5.5. 0-0.7.1474526,
VMware_bootbank_mtip32xx-native_3.3.4-1vmw.550.1.15.1623387, VMware_bootbank_netbe2net_4.6.100.0v-1vmw.550.0.0.1331820, VMware_bootbank_netbnx2_2.2.3d.v55.2-1vmw.550.0.0.1331820,
VMware_bootbank_net-bnx2x_1.72.56.v55.2-1vmw .550.0.0.1331820,
VMware_bootbank_net-cnic_1.72.52.v55.1-1vmw.550.0.0.1331820,
VMware_bootbank_net-e1000e_1.1.2-4vmw.550.1.15.1623387,
VMware_bootbank_net-igb_5 .0.5.1.1-1vmw.550.1.15.1623387,
VMware_bootbank_net-ixgbe_3.7.13.7.14iov-11vmw.5 50.0.0.1331820,
VMware_bootbank_net-nx-nic_5.0.621-1vmw.550.0.0.1331820,
VMware_ bootbank_net-tg3_3.123c.v55.5-1vmw.550.1.15.1623387,
VMware_bootbank_qlnativefc_ 1.0.12.0-1vmw.550.0.0.1331820,
VMware_bootbank_rste_2.0.2.0088-4vmw.550.1.15.162 3387,
VMware_bootbank_sata-ahci_3.0-18vmw.550.1.15.1623387,
VMware_bootbank_scsi -bnx2fc_1.72.53.v55.1-1vmw.550.0.0.1331820,
VMware_bootbank_scsi-bnx2i_2.72.11.v 55.4-1vmw.550.0.0.1331820,
VMware_bootbank_scsi-hpsa_5.5.0-44vmw.550.0.0.1331820 ,
VMware_bootbank_scsi-lpfc820_8.2.3.1-129vmw.550.0.0.1331820,
VMware_bootbank_s csi-megaraid-sas_5.34-9vmw.550.1.15.1623387,
VMware_bootbank_scsi-mpt2sas_14.00. 00.00-3vmw.550.1.15.1623387,
VMware_bootbank_scsi-qla4xxx_5.01.03.2-6vmw.550.0.0 .1331820,
VMware_locker_tools-light_5.5.0-1.15.1623387
VIBs Removed: Broadcom_bootbank_misc-cnic-register_1.78.1.v55.7-1OEM.550.0.0. 1198611, Broadcom_bootbank_net-bnx2_2.2.3t.v55.7-1OEM.550.0.0.1198611, Broadcom_ bootbank_net-bnx2x_1.78.28.v55.2-1OEM.550.0.0.1198611, Broadcom_bootbank_net-cni c_1.78.12.v55.6-1OEM.550.0.0.1198611, Broadcom_bootbank_net-tg3_3.133d.v55.1-1OE M.550.0.0.1198611, Broadcom_bootbank_scsi-bnx2fc_1.78.16.v55.4-1OEM.550.0.0.1198 611, Broadcom_bootbank_scsi-bnx2i_2.78.11.v55.4-1OEM.550.0.0.1198611, Emulex_boo tbank_elxnet_10.0.575.7-1OEM.550.0.0.1198611, Emulex_bootbank_lpfc_10.0.575.8-1O EM.550.0.0.1198611, Hewlett-Packard_bootbank_scsi-hpsa_5.5.0.50-1OEM.550.0.0.119 8611, Intel_bootbank_net-igb_4.2.16.8-1OEM.550.0.0.1198611, Intel_bootbank_net-i xgbe_3.15.1.8-1OEM.550.0.0.1198611,LSI_bootbank_scsi-mpt2sas_15.10.05.00.1vmw-1 OEM.550.0.0.1198610, QLogic_bootbank_ima-qla4xxx_500.2.01.31-1vmw.0.3.040121, QL ogic_bootbank_qlnativefc_1.1.7.0-1OEM.550.0.0.1198610, QLogic_bootbank_scsi-qla4 xxx_634.55.20.0-1OEM.550.0.0.1198610,
VMware_bootbank_esx-base_5.5.0-0.0.1331820 ,
VMware_bootbank_lsi-msgpt3_00.255.03.03-1vmw.550.0.0.1331820,
VMware_bootbank_ misc-drivers_5.5.0-0.0.1331820,
VMware_bootbank_mtip32xx-native_3.3.4-1vmw.550.0 .0.1331820,
VMware_bootbank_net-e1000e_1.1.2-4vmw.550.0.0.1331820,
VMware_bootba nk_net-nx-nic_5.5.634-3vmw.550.0.0.1198611,
VMware_bootbank_rste_2.0.2.0088-4vmw .550.0.0.1331820,
VMware_bootbank_sata-ahci_3.0-17vmw.550.0.0.1331820,
VMware_bo otbank_scsi-megaraid-sas_5.34-9vmw.550.0.0.1331820,
VMware_locker_tools-light_5. 5.0-0.0.1331820
VIBs Skipped: VMware_bootbank_ata-pata-amd_0.3.10-3vmw.550.0.0.1331820,
VMwar e_bootbank_ata-pata-atiixp_0.4.6-4vmw.550.0.0.1331820,
VMware_bootbank_ata-pata- cmd64x_0.2.5-3vmw.550.0.0.1331820,
VMware_bootbank_ata-pata-hpt3x2n_0.3.4-3vmw.5 50.0.0.1331820,
VMware_bootbank_ata-pata-pdc2027x_1.0-3vmw.550.0.0.1331820,
VMwa re_bootbank_ata-pata-serverworks_0.4.3-3vmw.550.0.0.1331820,
VMware_bootbank_ata -pata-sil680_0.4.8-3vmw.550.0.0.1331820,
VMware_bootbank_ata-pata-via_0.3.3-2vmw .550.0.0.1331820,
VMware_bootbank_block-cciss_3.6.14-10vmw.550.0.0.1331820,
VMwa re_bootbank_ehci-ehci-hcd_1.0-3vmw.550.0.0.1331820,
VMware_bootbank_esx-dvfilter -generic-fastpath_5.5.0-0.0.1331820,
VMware_bootbank_esx-tboot_5.5.0-0.0.1331820 ,
VMware_bootbank_esx-xlibs_5.5.0-0.0.1331820,
VMware_bootbank_esx-xserver_5.5.0 -0.0.1331820,
VMware_bootbank_ipmi-ipmi-devintf_39.1-4vmw.550.0.0.1331820,
VMwar e_bootbank_ipmi-ipmi-msghandler_39.1-4vmw.550.0.0.1331820,
VMware_bootbank_ipmi- ipmi-si-drv_39.1-4vmw.550.0.0.1331820,
VMware_bootbank_lsi-mr3_0.255.03.01-1vmw. 550.0.0.1331820,
VMware_bootbank_net-e1000_8.0.3.1-3vmw.550.0.0.1331820,
VMware_ bootbank_net-enic_1.4.2.15a-1vmw.550.0.0.1331820,
VMware_bootbank_net-forcedeth_ 0.61-2vmw.550.0.0.1331820,
VMware_bootbank_net-mlx4-core_1.9.7.0-1vmw.550.0.0.13 31820,
VMware_bootbank_net-mlx4-en_1.9.7.0-1vmw.550.0.0.1331820,
VMware_bootbank _net-vmxnet3_1.1.3.0-3vmw.550.0.0.1331820,
VMware_bootbank_ohci-usb-ohci_1.0-3vm w.550.0.0.1331820,
VMware_bootbank_sata-ata-piix_2.12-9vmw.550.0.0.1331820,
VMwa re_bootbank_sata-sata-nv_3.5-4vmw.550.0.0.1331820,
VMware_bootbank_sata-sata-pro mise_2.12-3vmw.550.0.0.1331820,
 VMware_bootbank_sata-sata-sil24_1.1-1vmw.550.0.0 .1331820,
VMware_bootbank_sata-sata-sil_2.3-4vmw.550.0.0.1331820,
VMware_bootban k_sata-sata-svw_2.3-3vmw.550.0.0.1331820,
VMware_bootbank_scsi-aacraid_1.1.5.1-9 vmw.550.0.0.1331820,
VMware_bootbank_scsi-adp94xx_1.0.8.12-6vmw.550.0.0.1331820,
VMware_bootbank_scsi-aic79xx_3.1-5vmw.550.0.0.1331820,
VMware_bootbank_scsi-fni c_1.5.0.4-1vmw.550.0.0.1331820,
VMware_bootbank_scsi-ips_7.12.05-4vmw.550.0.0.13 31820,
VMware_bootbank_scsi-megaraid-mbox_2.20.5.1-6vmw.550.0.0.1331820,
VMware_ bootbank_scsi-megaraid2_2.00.4-9vmw.550.0.0.1331820,
VMware_bootbank_scsi-mptsas _4.23.01.00-9vmw.550.0.0.1331820,
VMware_bootbank_scsi-mptspi_4.23.01.00-9vmw.55 0.0.0.1331820,
VMware_bootbank_scsi-qla2xxx_902.k1.1-9vmw.550.0.0.1331820,
VMwar e_bootbank_uhci-usb-uhci_1.0-3vmw.550.0.0.1331820
~ #


Raporları oluşturmak için Flex üzerindeki master server'a PuTTY üzerinden appadmin ile giriş yapın ve "sudo -i" ile root kulla...